H2U2U 电源
This full AC input range industrial level power supply offers the total power capacity of up to 600 Watts and uses APFC (Active Power Factor Correction) circuit design. It has quality components built in to provide 80 PLUS® efficiency and long term reliability. This product complies with IEC1000-3-2 and EN61000-3-2 PFC harmonics standards and Seasonic’s proprietary Smart and Silent Fan Control (S2FC) makes this unit operate at low noise levels. Most importantly, the SS-600H2U is a fully modular power supply that will make installation straightforward and easy.
产品概述
H1U | L1U | H2U | L2U | |
---|---|---|---|---|
80PLUS | 80PLUS | Gold | 80PLUS | Gold |
Intel EPS1U v2.1 compliant | Yes | Yes | Yes | Yes |
ATX 12 V v2.2 compliant | Yes | Yes | Yes | Yes |
Dimensions | 235 mm (L) x 100 mm (W) x 40 mm (H) | 235 mm (L) x 100 mm (W) x 40 mm (H) | 400 W and 460 W: 225 mm (L) x 100 mm (W) x 70 mm (H) 600 W: 270 mm (L) x 100 mm (W) x 70 mm (H) |
245 mm (L) x 100 mm (W) x 70 mm (H) |
DC to DC converter design | No | Yes | No | Yes |
Forward converter circuit | Yes | No | Yes | No |
Fully modular cables | Yes | Yes | Yes | Yes |
Fixed cables | No | No | No | No |
40 mm double ball bearing fan | Yes | Yes | No | No |
60 mm double ball bearing fan | No | No | Yes | Yes |
S3FC - including Fanless mode | No | Yes | No | Yes |
S2FC - Smart and Silent Fan Control | Yes | No | Yes | No |
Easy-swap connector design | No | No | No | No |
Zero minimum load on 3.3 V rail | Yes | Yes | Yes* * Not applicable to 600 W |
Yes |
Short circuit protection on all outputs | Yes | Yes | Yes | Yes |
Over voltage protection | Yes | Yes | Yes | Yes |
Over power protection | Yes | Yes | Yes | Yes |
100 % HiPot test | Yes | Yes | Yes | Yes |
100 % Burn-in, high temperature cycled on/off | Yes | Yes | Yes | Yes |
Safety compliance | CB, cUL, TUV, CCC, BSMI | CB, cUL, TUV, BSMI | CB, cUL, TUV, CCC, BSMI* * Not applicable to 600 W |
CB, cUL, TUV, BSMI |
EMI/EMC compliance | CE, FCC, RCM | CE, FCC, RCM | CE, FCC, RCM* * Not applicable to 600 W |
CE, FCC, RCM |
产品照片
产品规格
SS-600H2U
Specifications | |
---|---|
Input frequency | 50 / 60 Hz |
Hold up time, full load | 16 ms (typical) |
Efficiency (220 V AC - 240 V AC, full load) | 83 % (typical) |
Efficiency (100 V AC - 120 V AC, full load) | 80 % (typical) |
Dielectric withstand, input to frame/ground | 1800 VAC, 1 sec |
Dielectric withstand, input to output | 1800 VAC, 1 sec |
Line regulation | ± 1 % (typical) |
Load regulation | ± 5 % (typical) |
Cross regulation | ± 5 % (typical) |
MTBF, full load @ 25 °C ambient (excl. DC fan) | > 100,000 hours |
Active Power Factor Correction | 99 % (typical) |
DC Outputs | ||||||
---|---|---|---|---|---|---|
+3.3 V | +5 V | +12 Combined | -12 V | +5 Vsb | Total continuous power | Input Type |
20 A | 25 A | 45 A | 0.8 A | 3 A | 600 W | 100–240 VAC |
150 W (max.) | 544 W | 9.6 W | 15 W |